Exposure meter
Meaning of the delivery status
Immediately available
The item is in stock and can be shipped at short notice.
The item is also in stock in our shop in Düsseldorf.
Am Außenlager. Lieferzeit 4-6 Werktage nach Zahlungseingang
Der Artikel ist vor Ort in unserem Hauslager nicht vorrätig und wird nach erteiltem Kundenauftrag am Außenlager/beim Hersteller bzw. Distributor bestellt. Die zu erwartende Lieferzeit beträgt 4-6 Werktage.
Item has been ordered
The item has already been ordered from the manufacturer or distributor. The delivery time is usually between 1 week and 2 months. As soon as a more precise delivery time is known, we will publish the details on our website. After placing the order, you will be informed regularly about the delivery time.
Available at a specified date
The item has already been ordered from the manufacturer or distributor. We have been informed of the expected delivery date.
This item is ordered exclusively for you
The item is currently not in stock and will be ordered for you from the manufacturer or distributor after you have placed an order. The delivery time is usually between 1 week and 2 months. After placing the order, you will be informed regularly about the delivery time.
Item has been ordered. Delivery time 1-3 months
The item is currently not available. We were not given a delivery time. Experience shows that the expected delivery time is 1-3 months.
Currently not available
The manufacturer or supplier cannot confirm a date, so we assume a waiting time of 2 to 9 months. You can still order the item and secure your place on the waiting list.
Please note: Despite updating our website regularly, it is possible that an item may be out of stock but shown as available for a short time, especially when orders are high. All information is therefore without guarantee. We will inform you immediately if there is a delay in the expected availability/delivery time. The availability information refers to an order quantity of 1. Availability may vary for higher order quantities.
Delivery alarm
You would like to be informed as soon as the item is in stock?
Notification when the product is back in stock No reservation and no place on the waiting listYou want to reserve the product?
Order now, pay later (prepayment) Notification when the product is back in stock Product reservation and fixed place on the waiting list Cancellable at any time free of charge (until delivery)
The use of light meters in photography for optimally exposed photos
Exposure matched to the subject plays a fundamental role in photography. To achieve this, the light meter is of central importance, which is the subject of this article. In the course of this, you will also receive information about the use of the meter as well as the zone system of Ansel Adams.
What are light meters?
The light meter can be used to measure the brightness of the object to be photographed in order to make the appropriate settings for the aperture and exposure time on the camera. Almost all modern cameras have an integrated light meter that converts the measured values into an exposure value (automatic exposure) or allows manual settings. There is also the option of external metering. These handheld exposure meters are mostly used by professional photographers who work with artificial light (flash, continuous light) in the photo studio.
What are light meters used for?
Exposure meters can measure the amount of light falling on or reflected from a subject. Especially when the light intensity is not uniform within the photographed scene, setting the appropriate values using the light meter can make the difference between a properly exposed photo and a poor one. Cameras with built-in light meters use reflected light metering, where the reflected light from the camera is used to measure exposure. External exposure meters, on the other hand, measure the amount of light falling on a subject, for which the meter is placed near the subject. In contrast to reflection metering, the light is measured before it can be reflected by the subject. This incident light measurement also allows the light output of several flash heads used to be measured individually, which means that the various light sources can be controlled separately.
How to use a light meter?
When using the built-in reflected light metering, readings should be taken from different areas of the subject, for example dark shadow areas, bright light areas, and center zones. The meter can then automatically average the final exposure value and apply it to the camera's settings. For incident light metering, the external meter should be held in front of the camera. When doing this, make sure that the same light in the scene also falls on the exposure meter. After pressing the exposure meter button, the results can be read and the shutter and aperture of the camera can be adjusted accordingly
Zone system by Ansel Adams
The Zone System is a standardized way of working that guarantees correct exposure in any situation. The scale consists of eleven tonal values, the darkest value is pure black, the lightest value is pure white. Consequently, black is zone 0 and white is zone 10. The zones are defined by Roman numerals, with the middle tone value being in zone V (5) and having a reflectance of 18%. For digital photographers, zones 3 to 7 are particularly relevant, so that the darkest part of a subject is in zone 3 and the lightest part in zone 7. Consequently, everything below zone 3 is underexposed and everything above zone 7 is overexposed. For example, if the metering was based on a dark object in the background (Zone 3), photographers will need to underexpose by two stops from the average Zone 5 to reasonably expose the photo. Gray cards that are in the gray midtone (Zone V) serve as an additional tool for metering exposure.